Sale!
, ,

Laminar Air Flow LAFC-V1 – Advanced Vertical Clean Air Workstation for Laboratory Excellence

Original price was: 145,000.00৳ .Current price is: 135,000.00৳ .

Laminar Air Flow LAFC-V1

LAFC-V1

place of origin                :         China

warranty                         :         1 Year

customized support       :         OEM, ODM

brand name                   :         Wincom

model number               :         LAFC-V1

Product Name               :         Laminar Air Flow Cabinet

Flow direction                :         Vertical/Horizontal

Cleanliness Grade         :         100Grade@≥0.5u m(209E)

Number of colony          :         ≤0.5 (90) mm culture dish

Average wind speed      :         0.3~0.6 m/s (adjustable)

Classification                 :         Laboratory Thermostatic Devices

 

Product Description

Stainless steel laminar air flow hood
Stainless steel laminar air flow hood(LAFC-V1) is a kind of clean bench widely used in medical treatment, chemical experiment, electron, precise machinery, instrument, apparatus, medical preparation, operating room, foodstuff, drinks, daily-use cosmetic, stock raising and aviation, as well as providing germfree dustless clean environment.

Stainless steel laminar air flow hood(LAFC-V1)’s characteristics
1. The vertical closed bench can effectively prevent outer gas from entering and preventing peculiar smell in operating area from damaging human body.
2. Stainless steel laminar air flow hood adopts wind volume adjustable fan system, light-touch type switch and dual-speed voltage regulation device to keep wind speed in working area in ideal state.
3. The personalized design considers user’s demand completely. It adopts spring type sliding door so that the door can be oriented on needed position, thus it is more convenient to operate.
4. Stainless steel laminar air flow hood is the newest type bench in present market. The front cover may be opened directly for exchanging filter, electric components easily.
5 Operate with LED panel.
6The material of the work area is 304 stainless steel.

 

 

Art.No.: LAFC-V1 LAFC-V1D LAFC-V2 LAFC-V2D
Application of number 1People in 1Side Type 1People in 2Sides Type 2Peoples in 1Side Type 2Peoples in 2Sides Type
Flow direction Vertical Horizontal
Cleanliness Grade 100Grade@≥0.5u m(209E)
Number of colony ≤0.5 (Φ90) mm culture dish
Average wind speed 0.3~0.6 m/s (adjustable)
Illuminance ≥300LX (operation center)
Vibration and semi-peak value ≤ 3 u m ≤ 4 u m ≤ 3 u m
Specification and quantity of (HEPA)S 820x660x50x1 610x610x50x2
Size of working room (mm) 880x660x500 880x700x500 1310x660x500 1310x700x500

 

Introduction to Unmatched Laboratory Sterility

In contemporary scientific research, pharmaceutical manufacturing, biotechnology, and clinical diagnostics, maintaining a contaminant-free environment is paramount. Microscopic airborne particles, dust, and bacterial spores pose a constant threat to sensitive biological samples, culture media, and high-precision electronic assemblies. To protect these critical workflows from environmental contamination, the Laminar Air Flow LAFC-V1 offers a robust, reliable, and high-performance solution. Designed to establish an ultra-clean localized workspace, this vertical laminar flow cabinet meets the rigorous demands of modern laboratories seeking uncompromising safety and precision.

Core Engineering and Unidirectional Airflow Principle

The operational integrity of the Laminar Air Flow LAFC-V1 is built upon the principles of laminar and unidirectional airflow dynamics. Ambient room air is initially drawn into the system through a pre-filter designed to capture larger particulate matter, lint, and debris. Following pre-filtration, a high-performance blower pressurizes the air and forces it through a state-of-the-art High-Efficiency Particulate Air (HEPA) filter.

In the Laminar Air Flow LAFC-V1, this filtration mechanism produces Grade 100 cleanliness (equivalent to ISO 14644-1 Class 5) for particles $\ge 0.5\,\mu\text{m}$. The purified air streams vertically downward from the top of the cabinet over the entire work surface in a smooth, parallel pattern. This continuous downward sweep effectively displaces and flushes out any aerosols or particulate matter generated during handling, preserving a sterile barrier over the critical zone.

Technical Specifications and Performance Parameters

Engineered for strict operational accuracy, the Laminar Air Flow LAFC-V1 delivers exceptional technical metrics:

  • Airflow Configuration: Vertical unidirectional flow tailored for single-person, single-side utilization.

  • Cleanliness Certification: ISO Class 5 / Grade 100 compliance at $\ge 0.5\,\mu\text{m}$.

  • Wind Velocity: Finely adjustable average wind speed ranging from $0.3\text{ m/s}$ to $0.6\text{ m/s}$.

  • Microbial Control: Extremely low contamination metrics, maintaining $\le 0.5$ colonies per $\Phi 90\text{ mm}$ culture dish.

  • Workspace Illumination: Integrated lighting yielding $\ge 300\text{ LX}$ at the operational center to eliminate shadows and reduce operator fatigue.

  • Vibration Dampening: Low-vibration architecture engineered to maintain semi-peak vibration values $\le 3\,\mu\text{m}$, ensuring precision during delicate micro-manipulations.

Superior Structural Integrity and Material Excellence

Built to endure the heavy demands of daily laboratory use and aggressive sterilization protocols, the Laminar Air Flow LAFC-V1 features an exceptionally durable build. The interior workspace dimensions ($880 \times 660 \times 500\text{ mm}$) provide generous area for routine sample preparation while maintaining a footprint optimized for standard lab benches. The work surface is crafted from high-grade stainless steel, which resists chemical corrosion, prevents microbial colonization, and easily withstands frequent decontamination cycles using standard laboratory disinfectants such as 70% isopropyl alcohol or bleach solutions.

Diverse Applications Across Key Industries

The versatility and reliability of the Laminar Air Flow LAFC-V1 make it an indispensable asset across multiple professional fields:

  1. Microbiology and Cell Culture: Safeguards media, cellular inoculants, and microbial samples against cross-contamination during transfer processes.

  2. Pharmaceutical Compounding: Establishes a sterile framework for the preparation of specialized medications, sterile buffers, and intravenous admixtures.

  3. Plant Micropropagation: Provides a contamination-free zone essential for explant initiation, tissue culture, and callus maintenance.

  4. Electronics and Precision Assembly: Prevents micro-dust accumulation on sensitive semiconductor components, microchips, and optical instruments during assembly phases.

Why Choose the Laminar Air Flow LAFC-V1?

Choosing the Laminar Air Flow LAFC-V1 means committing to accuracy, regulatory compliance, and maximum sample protection. Its intuitive control interface, coupled with advanced HEPA filtration mechanics, ensures that your critical procedures remain shielded from fluctuating environmental pollutants. By stabilizing airflow patterns and minimizing turbulence, this unit minimizes experimental errors and enhances overall laboratory productivity. Elevate your facility’s contamination control standards today with the dependable precision of the Laminar Air Flow LAFC-V1.

(Bullet Points for E-commerce Page)

  • HEPA Filtration: High-efficiency particulate air filter capturing 99.99% of particles $\ge 0.3\,\mu\text{m}$.

  • Compact Footprint: Ideal design for single-person laboratory setups without sacrificing internal workspace.

  • Low Noise Operation: Engineered with low-vibration and quiet blowers to ensure a comfortable work environment.