Laminar Air Flow SF-CJ-1A – High-Performance Single-Person Vertical Clean Air Bench

  • Model NO                               :           SF-CJ-1A
  • Structure                                 :           Stainless Steel Laminar Air Flow Hood
  • Certification                            :           CE
  • Type                                        :           Heating Type
  • Brand Name                            :           WINCOM
  • After-Sales Service Provided :           No Overseas Service Provided
  • Clean Level                             :           Class 100
  • Size                                         :           1050*680*1600mm
  • Product Name                         :           Stainless Steel Laminar Air Flow Hood
  • Specification                           :           GMP
  • Customized                             :           Customized
  • Material                                   :           Stainless Steel
  • Air Supply                               :           Vertical Air
  • Trademark                               :           Suing
  • Origin                                      :            China

Product Description

Stainless steel laminar air flow hood(SF-CJ-1A)
Stainless steel laminar air flow hood(SF-CJ-1A) is a kind of clean bench widely used in medical treatment, chemical experiment, electron, precise machinery, instrument, apparatus, medical preparation, operating room, foodstuff, drinks, daily-use cosmetic, stock raising and aviation, as well as providing germfree dustless clean environment.

Stainless steel laminar air flow hood(SF-CJ-1A)’s characteristics
1. The vertical closed bench can effectively prevent outer gas from entering and preventing peculiar smell in operating area from damaging human body.
2. Stainless steel laminar air flow hood(SF-CJ-1A) adopts wind volume adjustable fan system, light-touch type switch and dual-speed voltage regulation device to keep wind speed in working area in ideal state.
3. The personalized design considers user’s demand completely. It adopts spring type sliding door so that the door can be oriented on needed position, thus it is more convenient to operate.
4. Stainless steel laminar air flow hood(SF-CJ-1A) is the newest type bench in present market. The front cover may be opened directly for exchanging filter, electric components easily.
5 Operate with LED panel.
6The material of the work area is 304 stainless steel.

No. Index/Model SF-CJ-1A Stainless steel laminar air flow hood
Cleaning level Grade 100(209E U.S. Federal)
Number of bacteria ≤0.5per utensil. Hour(90mm utensil)
The average wind speed 0.25~0.45m/s(Speed two-speed)
Noise ≤62dB
Power supply AC, 220 V/50Hz
Illumination ≥300LX
Half ventilation peak value ≤ 3μm(XYZ direction)
Max. power consumption 400W
Weight 75KG
Dimension of working area(W1×D1×H1) 870*600*520mm
Overall dimension W*D*H 1050*680*1600mm
Efficient filter specifications and quantities 865*555*38*1
Specification and number of fluorescent lamp or UV lamp of ultraviolet lights 8W*1/10W*1
Suited number Single-Double

Introduction to Uncompromised

 Cleanliness

In modern scientific research, pharmaceuticals, electronics assembly, and plant tissue culture, maintaining an environment free from particulate contamination is not merely a preference—it is an absolute necessity. Airborne contaminants, dust, and microbial spores can easily compromise sensitive samples, ruin experimental results, and invalidate months of meticulous work. To combat these challenges, the Laminar Air Flow SF-CJ-1A stands out as an elite solution. Designed to create a localized, ultra-clean workspace, this vertical laminar flow cabinet provides the rigorous protection required by today’s most demanding laboratory applications.

Core Engineering and Working Principle

The working principle of the Laminar Air Flow SF-CJ-1A relies on the physics of unidirectional airflow. Room air is drawn into the system through a pre-filter which traps larger dust particles and lint. The pre-cleaned air is then pressurized by a high-efficiency blower and pushed directly through a High-Efficiency Particulate Air (HEPA) filter.

For the Laminar Air Flow SF-CJ-1A, this filtration process achieves an exceptional Grade 100 cleanliness standard at $\ge 0.5\,\mu\text{m}$. Clean air flows vertically from the top of the cabinet downward across the entire work surface in a smooth, parallel stream. This constant sweeping action ensures that any particles generated on the work surface are immediately pushed away and out of the critical zone, maintaining an immaculate sterile envelope.

Key Technical Specifications and Performance Metrics

Precision and reliability are embedded into every aspect of the Laminar Air Flow SF-CJ-1A:

  • Airflow Pattern: Vertical unidirectional flow, optimized for single-person, single-side operations.

  • Cleanliness Grade: Grade 100 (ISO 14644-1 Class 5 equivalent) at $\ge 0.5\,\mu\text{m}$.

  • Wind Speed: Adjustable average wind velocity between $0.3\text{ m/s}$ and $0.6\text{ m/s}$, giving technicians precise control over environmental dynamics.

  • Colony Count: Maintains an extremely low number of colonies ($\le 0.5$ per $\Phi 90\text{ mm}$ culture dish).

  • Illumination and Ergonomics: Equipped with optimal internal lighting providing $\ge 300\text{ LX}$ at the operation center to reduce eye strain during delicate procedures.

  • Low Vibration Design: Engineered to keep semi-peak vibration values to $\le 3\,\mu\text{m}$, ensuring that microscopic manipulations remain steady and uninterrupted.

Superior Build Quality and Material Durability

Constructed from high-grade materials, the Laminar Air Flow SF-CJ-1A is built to withstand rigorous daily use and routine chemical sterilization. The interior working room dimensions offer ample space for routine procedures while keeping a compact footprint suited for standard laboratory benches. The stainless steel work surface resists corrosion, prevents bacterial harbouring, and can be easily sanitized with standard laboratory disinfectants like 70% ethanol or isopropyl alcohol.

Versatile Applications Across Industries

Due to its robust performance profile, the Laminar Air Flow SF-CJ-1A serves as an indispensable tool across diverse professional sectors:

  1. Microbiology and Biotechnology: Protects culture media, bacterial strains, and cellular inoculations from cross-contamination during transfer and analysis.

  2. Pharmaceutical Compounding: Ensures sterile preparation of medications, injectables, and compounded solutions.

  3. Plant Tissue Culture: Offers a sterile environment for explant preparation, micropropagation, and callus culture maintenance.

  4. Electronics and Medical Device Assembly: Prevents microscopic dust particles from settling on delicate microchips, sensors, or sensitive components during assembly.

Why Choose the Laminar Air Flow SF-CJ-1A?

Investing in the Laminar Air Flow SF-CJ-1A means prioritizing accuracy, compliance, and safety in your workflow. Its intuitive operation, combined with advanced HEPA filtration technology, guarantees that your samples remain shielded from ambient room pollutants. By minimizing turbulence and maintaining a steady, uniform barrier of clean air, this unit reduces experimental failure rates and elevates the overall quality of your output. Upgrade your laboratory infrastructure today with the dependable engineering of the Laminar Air Flow SF-CJ-1A and experience uninterrupted sterility for every project.

Additional Descriptions and Content Variations for Laminar Air Flow SF-CJ-1A

1. Short Descriptive Paragraph (For Product Cards & Quick Overviews)

The Laminar Air Flow SF-CJ-1A is an advanced single-person vertical clean bench engineered to deliver reliable ISO Class 5 sterile air conditions. Featuring high-efficiency HEPA filtration and a uniform unidirectional airflow design, this unit safeguards sensitive biological cultures, pharmaceutical preps, and micro-assemblies from airborne contamination. Its compact footprint, low-vibration engineering, and durable stainless steel work surface make it an essential asset for modern research and clinical laboratories.

2. Feature-Focused Bulleted Description (For Landing Pages & Brochures)

  • Optimized Sterile Environment: Generates an ISO Class 5 / Grade 100 clean air workspace to protect sensitive samples and cultures from particulate and microbial contamination.

  • Unidirectional Vertical Airflow: Ensures a smooth, downward stream of purified air that continuously flushes out aerosols and particulate matter generated during handling.

  • Adjustable Wind Velocity: Provides fine control with an average wind speed range of $0.3\text{ m/s}$ to $0.6\text{ m/s}$ to suit diverse procedural requirements.

  • High-Grade HEPA Filtration: Effectively traps microscopic particles and spores, maintaining an exceptionally clean environment with minimal colony counts ($\le 0.5$ per dish).

  • Ergonomic & Quiet Operation: Built with a low-vibration structure ($\le 3\,\mu\text{m}$) and integrated glare-free illumination ($\ge 300\text{ LX}$) to reduce fatigue during extended laboratory work.

  • Corrosion-Resistant Interior: Features a heavy-duty stainless steel workspace that withstands frequent sanitization with standard laboratory disinfectants.

3. Bulleted Highlights for E-commerce Feature Lists

  • Model: Laminar Air Flow SF-CJ-1A

  • Configuration: Single-person, single-side vertical clean air cabinet

  • Cleanliness Standard: ISO Class 5 / Grade 100 at $\ge 0.5\,\mu\text{m}$

  • Primary Applications: Microbiology, biotechnology, pharmaceutical compounding, and plant tissue culture