Sale!
,

Portable Autoclave Pressure Sterilizer Model AT-P18A for Lab & Medical Use

Original price was: 22,000.00৳ .Current price is: 20,000.00৳ .

Portable Autocalve (Pressure sterilizer)

MODEL: AT-P18A

Features:

*Stainless Steel,

*Non electrical;

*3(three) chambers;

*Size: Diameter 240~260mm, height 245~310mm

*Capacity: 13L;

*Heavy cast stainless steel chamber;

*All stainless steel deep drawn seamless construction;

Light, compact, portable, easy to use top loading autoclaves;

*Fast 20min, sterilizing cycle at 121° to 127°;

 

Equipped with 2(two) stages over pressure protection system incorporating a calibrated continuous breeding pressure stopcock and pressure release weight valve.

Extended life gasket and heating element(ISI or equivalent marked).

Equipped with heat resistant handles and steam release/control valve.

For assurance of quality each autocalve is tested to the parameter of successful sterilization.

Optional TST indicator stickers provide independent verification that the correct combination of temperature, steam & time ahs been achieved for successful sterilization.

Pressure ball/Gauge: colour coded pressure ball/gauge showing internal chamber conditions during the cycle. Sterilization zone in green colour is shown from 15psi to 18psi(OR 1.034 bar to 1.378 bar) which is equivalent to temperature of 121℃ to 127℃. Dial size: 2.5”. Dial show measurement in 2 units(i) kg/sq cm (ii) lb/sq inch. Full scale dial of pressure ball/gauge is 0-30lb/sq inch or 0-2kg/sq cm. Caution zone in red colour.

Inclusive of -inner & outer stand.

Optional: Inside three triangular baskets timer and spares.

Inside three triangular perforated baskets(Rack) will be such size and shape that accommodated within the sterilizer so that the three baskets are filled with three sets of IUD insertions kits instruments and can sterilized at a time as shown in the figure. The triangular perforated basket should be made of stainless steel. Lower 3.5cm-5cm will not be perforated so that the inside IUD insertion set will not be  wetted as shown in the figure.

 

 

Quality Standard:

-ISO and CE/USFDA Approved. Certificate must be submitted with the offer.

-Must be submitted ISI standard or Equivalent certificate.

-Specific product certificate for import by DGDA, Bangladesh as per drug policy.

 

Packing: Each set should be packed in a poly bag. 1set in one carton.

Marking of each pack: Manufacture’s name and country origin is to be hollow market on each IUD sterilizer

Labeling on the packaging:

  • -Name and/or trade mark and address of the manufacturer.
  • -Name of manufacturer and country of origin.
  • -Type of product and main characteristics.
  • -Expiry date by year and mouth, prefixed by the word “EXP”(or equivalent harmonized symbol) if applicable.
  • -A list of different parts of instrument should be provided with details information/specification in each poly carton.
  • -clearly market on each machine and carton

“Procured under CCSDP, DGFP”

Overview of Model AT-P18A Portable Autoclave

The Portable Autoclave (Pressure Sterilizer) Model AT-P18A is a high-performance sterilization device that utilizes saturated steam under pressure to achieve total destruction of bacteria, viruses, fungi, and spores. Built with robust materials and advanced safety controls, it is the ideal solution for clinics, field hospitals, veterinary practices, and research laboratories.

Key Features & Technical Benefits

  • Efficient Steam Sterilizer Design: Rapidly generates high-pressure steam to penetrate instrument packs and porous materials completely.

  • Durable Construction: Fabricated from high-grade stainless steel to resist corrosion, handle high temperatures, and ensure long-term operational life.

  • Integrated Safety Systems: Equipped with pressure release valves, dual safety valves, and a secure locking mechanism to prevent accidental opening under high pressure.

  • User-Friendly Operation: Features an intuitive pressure gauge and temperature indicator for precise monitoring throughout the sterilization cycle.

Applications

  • Medical & Dental Clinics: Perfect for sterilizing surgical instruments, forceps, and syringes.

  • Laboratories: Ideal for sterilizing glassware, petri dishes, and biological waste.

  • Field & Mobile Units: Compact footprint allows for easy transport and deployment in remote or temporary healthcare settings.

Frequently Asked Questions (FAQ) Pressure Sterilizer

  • What is the capacity of the Portable Autoclave AT-P18A? The AT-P18A model features a optimized chamber volume suitable for standard laboratory and clinical instrument loads.

  • What is the power source required to run this unit? It operates on standard electrical supply voltages with efficient heating elements designed for quick steam generation.

  • How do I ensure safety during operation? Always verify that the water level is sufficient, ensure the lid is securely locked, and never attempt to open the chamber until the pressure gauge drops to zero.

  • Can it sterilize wrapped instruments? Yes, the pressurized saturated steam effectively penetrates standard medical sterilization pouches and wraps.

Portable Autoclave (Pressure Sterilizer) Model AT-P18A: Comprehensive Guide

Introduction to Portable Sterilization Excellence

In modern medical clinics, dental offices, microbiological laboratories, and field research stations, maintaining absolute sterility is non-negotiable. The transmission of pathogens, spores, and cross-contamination poses severe risks to patient health and scientific integrity. To combat this, sterilization must be absolute, reliable, and accessible regardless of spatial limitations. Enter the Portable Autoclave Pressure Sterilizer Model AT-P18A—a state-of-the-art, compact sterilization powerhouse engineered to deliver hospital-grade steam sterilization performance in a mobile, user-friendly footprint. This device bridges the gap between bulky, stationary hospital sterilizers and the practical mobility required by field researchers and private practices.

Advanced Engineering and Build Quality Portable Steam Sterilizer

The foundation of any dependable pressure vessel lies in its metallurgy and structural design. The portable autoclave AT-P18A is constructed from heavy-duty, high-grade stainless steel, which offers exceptional resistance to thermal stress, physical impact, and long-term corrosion caused by continuous exposure to moisture and high heat.

  • Seamless Chamber Design: The inner sterilization chamber is polished and seamless, preventing the accumulation of biological residue and facilitating effortless cleaning between cycles.

  • Robust Lid and Sealing Mechanism: The heavy-duty lid features an integrated high-temperature silicone gasket that creates an airtight, hermetic seal under pressure. This ensures that no steam escapes prematurely, optimizing thermal efficiency and pressure buildup.

  • Ergonomic Handles: Designed with heat-resistant, insulated carrying handles, allowing users to transport or position the unit safely even shortly after a cycle concludes.

Working Principle and Operational Dynamics Medical Autoclave Machine

The portable autoclave operates on the fundamental principle of saturated steam under pressure. When water inside the internal reservoir is heated by the high-efficiency immersion heating elements, it boils and turns into steam. As the steam is trapped within the sealed chamber, the pressure rises proportionally with the temperature.

  • Penetration Power: Under elevated pressure (typically around 0.14 to 0.16 MPa) and temperature (reaching approximately 121°C to 126°C), steam penetrates deep into the pores of textiles, wrapped instrument packs, and hollow glassware.

  • Protein Coagulation: This intense moist heat rapidly denatures and coagulates the proteins within microorganisms, bacteria, viruses, fungi, and highly resilient bacterial endospores, ensuring 100% destruction within a standard 15-to-30-minute exposure cycle.

Integrated Safety Systems

Operating a pressurized vessel demands rigorous safety protocols. The portable autoclave model AT-P18A is equipped with multiple redundant safety features to protect operators and equipment:

  1. Automatic Pressure Release Valve: If internal pressure exceeds the safe operating threshold, the valve automatically vents excess steam to stabilize the internal environment.

  2. Dual-Action Safety Lock: The mechanical lid locking system ensures that the unit cannot be unsealed or opened while the chamber remains under high pressure, effectively eliminating the risk of accidental steam discharge burns.

  3. Visual Pressure and Temperature Gauges: An easy-to-read, analog pressure gauge mounted on the top cover provides real-time feedback, allowing the operator to monitor cycle progress precisely.

Wide-Ranging Applications Laboratory Sterilization Equipment

Due to its versatile thermal capabilities and portable design, the portable autoclave serves across numerous critical sectors:

  • Healthcare & Dental Clinics: Essential for sterilizing surgical scalpel blades, dental mirrors, forceps, hypodermic syringes, and metallic instruments.

  • Microbiology & Research Laboratories: Used extensively for sterilizing nutrient culture media, petri dishes, pipettes, and biological waste prior to disposal.

  • Veterinary Practices & Field Medic Units: Provides reliable animal surgery tool sterilization and quick-response instrument processing in remote clinics or mobile disaster relief camps.

Operating Instructions and Best Practices

  1. Water Preparation: Pour distilled or demineralized water into the bottom reservoir up to the designated water level marker. Avoid using tap water to prevent mineral scale buildup on the heating elements.

  2. Loading the Chamber: Arrange instruments, trays, or media bottles loosely inside the inner basket to allow unhindered steam circulation. Do not overcrowd the chamber.

  3. Sealing and Heating: Secure the lid tightly by evenly tightening the locking bolts. Turn on the power supply to initiate steam generation.

  4. Monitoring & Venting: Monitor the pressure gauge until it reaches the desired operating zone. Maintain the temperature for the required duration, then switch off the heater and allow the pressure to drop naturally to zero before unlocking the chamber.

Reviews

There are no reviews yet.

Be the first to review “Portable Autoclave Pressure Sterilizer Model AT-P18A for Lab & Medical Use”

Your email address will not be published. Required fields are marked *

Trustpilot